Project

General

Profile

Actions

Remote control

In this page are reported the messages exchanged when the operation is controlled by the remote app. The communication is started by 41 ( Hi-mit controller )

CYCLE 1 OFF WATER TEMP SET TO 11°C

SRC CTRL LEN DSW1 ADDR ? MODE CYCLE 1 WATER SET TEMP CYCLE 2 WATER SET TEMP DHW SET TEMP POOL SET TEMP CYCLE1 ENABLE CYCLE2 ENABLE? CYCLE1 ROOM1 SET TEMP CYCLE1 ROOM2 SET TEMP CYCLE1 ROOM3 SET TEMP CYCLE1 ROOM4 SET TEMP CYCLE2 ROOM1 SET TEMP CYCLE2 ROOM2 SET TEMP CYCLE2 ROOM3 SET TEMP CYCLE4 ROOM1 SET TEMP ROOM ENABLE CRC
41 0 48 202 160 1 1 107 62 31 8 255 11 12 45 24 0 0 26 28 28 28 28 28 28 28 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 211

ACK from 146

SRC CTRL LEN DSW8 ADDR - DSW8 ADDR CRC
146 0 14 1 1 1 0 99 62 0 31 9 255 187

ACK from 41

SRC CTRL LEN DSW8 ADDR - DSW8 ADDR CYCLE1 WATER TEMP SET TEMP CRC
146 0 12 1 1 1 0 99 62 3 11 88

ACK from 41

SRC CTRL LEN DSW1 ADDR ? CYCLE 1 WATER SET TEMP CYCLE 2 WATER SET TEMP DHW SET TEMP POOL SET TEMP CYCLE1 ENABLE CYCLE2 ENABLE? ROOM 1 SET TEMP ROOM1 ENABLE CRC
41 0 48 202 160 1 1 107 62 0 8 0 11 12 45 24 0 0 26 28 28 28 28 28 28 28 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 51

ACK from 146

SRC CTRL LEN DSW8 ADDR - DSW8 ADDR CRC
146 0 14 1 1 1 0 99 62 0 0 9 0 91

ACK from 41

CYCLE 1 OFF WATER TEMP SET TO 13°C

SRC CTRL LEN DSW1 ADDR ? CYCLE 1 WATER SET TEMP CRC
41 0 48 202 160 1 1 107 62 31 8 255 13 12 45 24 0 0 26 28 28 28 28 28 28 28 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 213

ACK from 146

SRC CTRL LEN DSW8 ADDR - DSW8 ADDR CRC
146 0 14 1 1 1 0 99 62 0 31 9 255 187

ACK from 41

SRC CTRL LEN DSW8 ADDR - DSW8 ADDR CYCLE1 WATER TEMP SET TEMP CRC
146 0 12 1 1 1 0 99 62 3 13 94

ACK from 41

SRC CTRL LEN DSW1 ADDR ? CYCLE 1 WATER SET TEMP CRC
41 0 48 202 160 1 1 107 62 0 8 0 13 12 45 24 0 0 26 28 28 28 28 28 28 28 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 53

ACK from 146

SRC CTRL LEN DSW8 ADDR - DSW8 ADDR CRC
146 0 14 1 1 1 0 99 62 0 0 9 0 91

ACK from 41

CYCLE 1 ON WATER TEMP SET TO 13°C

|41|0|48|202|160|1|1|107|62|31|8|255| 13 |12|45|24| 1 |0|26|28|28|28|28|28|28|28|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|212|
ACK from 146
|146|0|14|1|1|1|0|99|62|0|31|9|255|187|
ACK from 41
|146|0|12|1|1|1|0|99|62|1|9|88|
ACK from 41
|146|0|12|1|1|1|0|99|62| 2 | 16 |66| <- THESE TWO BYTES CHANGED !
ACK from 41
|50|0|14|1|1|1|0|1|9|2|1|3|13|10|
ACK from 35
|41|0|48|202|160|1|1|107|62|0|8|0| 13 |12|45|24| 1 |0|26|28|28|28|28|28|28|28|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|52|
ACK from 146
|146|0|14|1|1|1|0|99|62|0|0|9|0|91|
ACK from 41

Updated by Alessio Valeri 5 months ago · 27 revisions