Messages » History » Revision 11
Revision 10 (Alessio Valeri, 07/31/2025 07:44 PM) → Revision 11/351 (Alessio Valeri, 07/31/2025 07:51 PM)
# Messages ### ADDRESS FROM 41 ( HI-MIT INTERFACE ) |41|0|9|202|160|255|255|241|146| |41|0|9|202|160|1|1|97|2| |41|0|48|202|160|1|1|107|62|31|8|255|11|12|45|24|0|0|26|28|28|28|28|28|28|28|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|211| |41|0|48|202|160|1|1|107|62|0|8|0|11|12|45|24|0|0|26|28|28|28|28|28|28|28|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|51| ### ADDRESS FROM 146 ( MAIN CPU BOARD ) |146|0|12|1|1|1|0| **99** |62| **3** | **9** |90| <- VIENE INVIATO QUANDO IL MASTER CONTROLLER CAMBIA LA TEMPERATURA ACQUA CICLO 1 - PORTATA A 9°C |146|0|12|1|1|1|0| **99** |62| **3** | **11** |88| <- VIENE INVIATO QUANDO IL MASTER CONTROLLER CAMBIA LA TEMPERATURA ACQUA CICLO 1 - PORTATA A 11°C |146|0|12|1|1|1|0| **99** |62| **4** | **17** |69| <- VIENE INVIATO QUANDO IL MASTER CONTROLLER CAMBIA LA TEMPERATURA ACQUA CICLO 2 - PORTATA A 17°C |146|0|12|1|1|1|0| **99** |62| **10** | **22** |76| <- VIENE INVIATO QUANDO IL MASTER CONTROLLER CAMBIA LA TEMPERATURA AMB1 - 22°C *NOTA: 10 RAPPRESENTA AMB1 3 RAPPRESENTA TEMP ACQUA CICLO 1 4 RAPPRESENTA TEMP ACQUA CICLO 1 |146|0|12|1|1|1|0|99|62|4|17|69| |146|0|48|1|1|1|0|97|62|0|8|0| **11** |12|45|24|0|0|0|26|28|28|28|28|28|28|28|0|0|0|0|160|0|0|0|0|0|0|0|0|0|0|0|0|0|0|0|242| <- SEMBRA UN AGGIORNAMENTO DI STATO, EVIDENZIATA TEMP ACQUA